GB11
- use protective gloves.
- disconnect the appliance from the power supply.
GREASE FILTERS
The metal grease filter has an unlimited life and should be cleaned once a month by hand or in a dishwasher at low
temperature and with a short cycle. Cleaning in a dishwasher may cause discoloring of the grease filter, but its
filtering efficiency is unaffected.
Open the extraction panel (twist upwards).
Note: the panel does not need to be removed.
Pull out the handle to remove the filter.
Wash the filter and leave it to dry, proceeding in reverse order to refit.
CARBON FILTER
(filter hoods only)
It retains the unpleasant odors produced during cooking.
Change the carbon filter every 4 months
Fitting or changing the carbon filter
1. Disconnect the hood from the power supply.
2. Open the extraction panel and remove it.
3. Remove the grease filters.
4. Fit one carbon filter each side, covering both protection grilles of the motor impeller. Turn the filters
clockwise to secure them to the middle pins.
Proceed in reverse order to remove.
Re-fit the grease filters and extraction panel.
REPLACING HALOGEN LAMPS
- Only use 20W MAX - G4 halogen lamps.
1. Disconnect the hood from the household power supply.
2. Use a small screwdriver to gently prise (at the three points indicated) the lamp cover off.
3. Remove the burnt-out lamp and fit a new one.
4. Re-fit (snap-on) the lamp cover.
ATTENTION:
ATTENTION:
MAINTENANCE
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 63 64

Comments to this Manuals